TECHNICIAL SPECIFICATIONS |
Nominal power (kVA) | 300 |
INPUT |
Voltage | 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load) |
Frequency | 50Hz / 60Hz, ± %5 |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT |
Power (kW) | 270 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 95% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES |
Type | VRLA AGM / GEL / NiCd |
Battery Number | 2x30 (±30): 60 pieces |
Float charging voltage | 2x405 VDC |
Float / End of dischg voltage | 2x300 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 68 dBA |
Weight (kg) | 635 |
Dimension (mm) HxWxD | 1250x775x1900 |
OPTIONS |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at the input & output (internal) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 kullanıcı , T-Mon Server 50-100-200 kullanıc |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |