DS Power 300HT Online UPS uses the latest DSP technology, which can be programmed to suit a wide variety of electrical environments without impending its performance. With the 3-Level topology, efficiency, reliability and functionality have been raised to levels unattainable with old analog technology. This technology not only creates a significant increase in MTBF, but the DSP’s ability to accurately process signals at very high speed allows all UPS subsystems to be controlled with greatly increased precision. Thanks to its built-in inverter isolation transformer, it guarantees safe operation and provides uninterrupted energy for local networks, communication systems, sensitive medical devices, smart engineering measurement devices and industrial automation systems.
DS Power 300HT Online UPS uses the latest DSP technology, which can be programmed to suit a wide variety of electrical environments without impending its performance. With the 3-Level topology, efficiency, reliability and functionality have been raised to levels unattainable with old analog technology. This technology not only creates a significant increase in MTBF, but the DSP’s ability to accurately process signals at very high speed allows all UPS subsystems to be controlled with greatly increased precision. Thanks to its built-in inverter isolation transformer, it guarantees safe operation and provides uninterrupted energy for local networks, communication systems, sensitive medical devices, smart engineering measurement devices and industrial automation systems.
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 10 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 9 |
Power factor | 0,9 |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 336 VDC (2X28 batteries) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 280 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1 , EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 57 dBA |
Weight (kg) | 187 |
Dimension (mm) HxWxD | 400x815x1040 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 15 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 13,5 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 57 dBA |
Weight (kg) | 198,5 |
Dimension (mm) HxWxD | 400x815x1040 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 20 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 18 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 62 dBA |
Weight (kg) | 244 |
Dimension (mm) HxWxD | 400x815x1040 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 30 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 27 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 62 dBA |
Weight (kg) | 270 |
Dimension (mm) HxWxD | 400x815x1040 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 40 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 36 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 62 dBA |
Weight (kg) | 393 |
Dimension (mm) HxWxD | 515x855x1440 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 60 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 54 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 64 dBA |
Weight (kg) | 457 |
Dimension (mm) HxWxD | 515x855x1440 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 80 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 72 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 64 dBA |
Weight (kg) | 536 |
Dimension (mm) HxWxD | 515x855x1440 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 100 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 90 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 68 dBA |
Weight (kg) | 539 |
Dimension (mm) HxWxD | 825x855x1770 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 120 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 108 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 68 dBA |
Weight (kg) | 595 |
Dimension (mm) HxWxD | 825x855x1770 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 160 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 144 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 68 dBA |
Weight (kg) | 647 |
Dimension (mm) HxWxD | 825x855x1770 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 200 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 180 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 68 dBA |
Weight (kg) | 910,5 |
Dimension (mm) HxWxD | 825x855x1770 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 250 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 225 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | 72 dBA |
Weight (kg) | 1150 |
Dimension (mm) HxWxD | 1250x1055x1900 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 300 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 270 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | 72 dBA |
Weight (kg) | 1283 |
Dimension (mm) HxWxD | 1250x1055x1900 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 400 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 360 |
Power factor | 0,9 (0,8 and 1 optional) |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 312 VDC (2x26 batts) |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 351 VDC / ± 260 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
INDICATORS | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | 72 dBA |
Weight (kg) | 1497 |
Dimension (mm) HxWxD | 1250x1055x1900 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Nominal power (kVA) | 500 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz, ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 400 |
Power factor | 0.8 |
Voltage | 380/400 VAC 3P + N, ± 1% (415 VAC optional ) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 94% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | 2x28 batteries |
Float charging voltage | ± 378 VDC |
Float / End of dischg voltage | ± 280 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel |
Indicators | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Software (3 clients + 1 server management) |
Alarm Logging | Standard: with time & date 512 events |
Protections | Power module over-temperature, Over current, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | 72 dBA |
Weight (kg) | 2402 |
Dimension (mm) HxWxD | 2020x2250x770 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at input (optional) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | up to 8 units |
(*) | Depending on power and input/output conditions |
Nombre | Tamaño del Archivo | ||
---|---|---|---|
1) | DS POWER 300HT (10 - 500 kVA) |
En este sitio web se utilizan cookies para mejorar la experiencia del usuario y garantizar el funcionamiento eficiente del sitio web. Al utilizar este sitio web, acepta el uso de estas cookies. Para más información, POLÍTICA DE COOKIES